Ndezvipi zvakanakira parallel dizeli jenareta seti?

Nguva: 2018-09-15 Hits: 8

Ndezvipi zvakanakira parallel dizeli jenareta seti? Chokutanga pane zvose, tinofanira kunzwisisa kuti chii chiri kusanganiswa kwedizeli jenareta seti uye makabati. Iyo parallel cabinet zvakare generator automatic control cabinet.

 Kana maviri kana anopfuura maseti ejenareta akasanganiswa kuti ape simba kumutoro, kana kana imwe kana akawanda seti yejenareta akasanganiswa kuti ape simba kune grid, majenareta edhiziri seti anofanirwa kufananidzwa, kuitira kuti sisitimu igone kusangana nezvinodiwa zvejoint. magetsi uye kugadzira magetsi. Muchina unoshanda zvakajairika.

Zvakanakira zveparallel diesel generating sets:

 1. Kuvandudza kuvimbika uye kuenderera mberi kwegadziriro yemagetsi. Nekuti akawanda mayuniti akabatana akabatana kuti aumbe gidhi remagetsi, iyo voltage uye frequency yemagetsi emagetsi yakagadzikana uye inogona kumirisana nekukanganisa kwekuchinja kukuru kwemutoro.
 2. Kuchengetedza uye kugadzirisa zviri nyore. Zvikamu zvakawanda zvinogona kushandiswa zvakafanana, zvinogona kutumirwa nechepakati, uye kugoverwa mitoro inoshanda uye inoshanda, iyo inogona kuita kuti kugadzirisa nekugadzirisa kuve nyore uye nenguva.
 3. Zvimwe zvehupfumi. Zvinoenderana nehukuru hwemutoro wepamhepo, nhamba yakakodzera yeakaderera-simba mauniti anogona kuiswa kuti aderedze kutambisa mafuta neoiri anokonzerwa nediki-mutoro mashandiro emasimba makuru-simba.
 4. The future expansion is more flexible. Only need to install the power generation and parallel equipment of the current required power. When the company needs to expand the grid capacity in the future, it will add diesel generator sets, and the expansion of the generator sets can be easily realized in par

How long does the three filter element of the diesel generator set need to be replaced?

The three filter elements of diesel generator sets are divided into diesel filter, oil filter, and air filter. So how long does the three filter element of the diesel generator set need to be replaced?

1. The diesel filter needs to be replaced once after 400 hours of operation of the diesel generator set. The replacement cycle also depends on the quality of the diesel. If the quality of the diesel is poor, the replacement cycle needs to be shortened.
 2. The oil filter needs to be replaced once when the diesel generator set works for about 200 hours.
 3. The air filter is replaced according to the display of the indicator. If the air quality in the area where the diesel generator set is used is poor, the replacement cycle of the air filter should also be shortened.

 The above is the general situation of replacing the three filter elements of a diesel generator set, but the replacement period is different according to the use time of the area.llel, which makes the initial investment more Significant economy.